Thermal Science 2022 Volume 26, Issue 6 Part A, Pages: 4819-4829
https://doi.org/10.2298/TSCI220212078I
Full text (
870 KB)
Cited by
New concept of in/out air quality control in livestock buildings
Ivanišević Mladen S.
(University of Novi Sad, Faculty of Agriculture, Novi Sad, Serbia), mladen.ivanisevic@polj.uns.ac.rs
Zoranović Miodrag S. (University of Novi Sad, Faculty of Agriculture, Novi Sad, Serbia)
Topisirović Goran R.
(University of Belgrade, Faculty of Agriculture, Belgrade - Zemun, Serbia)
Jugović Milan A.
(University of East Sarajevo, Faculty of Agriculture, East Sarajevo, Bosnia and Herzegovina)
Rajs Vladimir M.
(University of Novi Sad, Faculty of Technical Sciences, Dositeja Obradovića, Novi Sad, Serbia)
Vejnović Srđan M. (University of Novi Sad, Faculty of Agriculture, Novi Sad, Serbia)
Kešelj Krstan R.
(University of Novi Sad, Faculty of Agriculture, Novi Sad, Serbia)
The object of this research is the new concept of the original universal system for air quality and energy control in laboratory conditions (wet scrubbing system) based on the „clean air in/out“ principle. Namely, the process involves a partial or complete exchange of recirculated treated air. From the aspect of water, as a pure medium, the system is characterized by broad application in the open, semi-open, and closed air treatment systems: primarily in the breeding and accompanying agricultural facilities, industrial, cultural, sports, tourist, medical and other controlled spaces. The analysis showed that the system at its inlet unit and with the block structure and logical phase development, proved energy, environ-mental and qualitative efficiency in the removal of PM10 and PM2.5 particles from the controlled dust doses in laboratory air. The measurements of PM10 and PM2.5 concentrations were performed with two Alphasense OPC-N3 optical counters at the inlet and outlet of the system. Five operating regimes with frequency regulated number of revolutions of the turbo elements that was taken as an independent variable, achieved different degrees of removal of PM10 and PM2.5 from the treated laboratory air: 97.70-98.53% and 62.19-75.75%, respectively. The assessment of system energy use was done by parallel measuring of electric power and comparative deviations of its absolute values in the first decimal. Energy consumption for the treatment of 1m3 of air ranged from 0.00011- 0.00016 kWm–3. Statistical analysis of qualitative indicators revealed significant differences between the operating regimes and the obtained values.
Keywords: Air quality, PM, wet purification, ventilation, livestock, energy
Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 451-03-9/2021-14/200117
Show references
Takai, H., et al., Concentrations and Emissions of Airborne Dust in Livestock Buildings in Northern Europe, Journal of Agricultural Engineering Research, 70 (1998), 1, pp. 59-77
Wathes, C. M., Ventilation in Stables, Farm Buildings and Engineering, 6 (1989), pp. 21-25
Banhazi, T. M., et al., Identification of the Risk Factors for High Airborne Particle Concentrations in Broiler Buildings Using Statistical Modeling, Biosystems Engineering, 101 (2008), 1, pp. 100-110
Donham, K. et al., Environmental and Health Studies of Farm Workers in Swedish Swine Confinement Buildings, Occupational and Environmental Medicine, 46 (1989), 1, pp. 31-37
Harry, E. G., Air pollution in Farm Buildings and Methods of Control - Review, Avian Pathology 7 (1978), 4, pp. 441-454
Carpenter. G, A., Dust in Livestock Buildings - Review of Some Aspects, Journal of Agriculture Engi-neering Research. 33 (1986), 4, pp. 227-241
Takai, H., et al., Ammonia Contents and Desorption from Dusts Collected in Livestock Buildings, Agric. Eng. International: CIGR J. Scientific Res. and Development, 4 (2002), 11
Banhazi, T. M., et al., Identification of Risk Factors for Sub-Optimal Housing Conditions in Australian Piggeries: Part 2. Airborne Pollutants, Journal of Agricultural Safety and Health, 14 (2008), 1, pp. 21-39
Bottcher, R. W., An Environmental Nuisance: Odor Concentrated and Transported by Dust, Chem. Senses, 26 (2001), 3, pp. 327‐331
Takai, H., et al., Dust Concentrations in Animal Indoor Environments in Northern Europe. In Proceed-ings, 5th International Symposium on Livestock Environment, Bloomington, Minn., USA, 1997, pp. 504-511
Tan, Z., Zhang, Y., A Review of Effects and Control Methods of Particulate Matter in Animal Indoor Environments, Air & Waste Management Association, 54 (2004), pp. 845-854
Cermak, J. P., Ross, P. A., Airborne Dust Concentrations Associated with Animal Housing Tasks, Farm Build. Prog., 51 (1978), pp. 11-15
Pearson, C. G., Air Cleaning for Livestock Production Buildings, Farm Build. Environ., 5 (1988), 2, pp. 13-17
Pearson, C. C., Sharples, T. J., Airborne Dust Concentrations in Livestock Buildings and the Effect of Feed, Journal of Agricultural Engineering Research, 60 (1995), 3, pp. 145-154
Dawson, J. R., Minimizing Dust in Livestock Buildings: Possible Alternatives to Mechanical Separation, Journal of Agricultural Engineering Research, 47 (1990), Sept.-Dec., pp. 235-248
Nowak, D., Health Effects of Airborne Pollutants, Particularly in Swine Confinement Stalls, from the Viewpoint of Occupational Medicine, Dtsch Tierarztl Wochenschr, 105 (1998), 6, pp. 225-234
Hoek, G., et al., Daily Mortality and Air Pollution in The Netherlands, Journal of the Air and Waste Management Association 50 (2000), 8, pp. 1380-1389
Pope, C. A., et al., Lung Cancer, Cardiopulmonary Mortality, and Long-Term Exposure to Fine Particu-late Air Pollution, The Journal of the American Medical Association 287 (2002), 9, pp. 1132-1141
Andersen, C. I., et al., Respiratory Symptoms and Airway Obstruction in Swine Veterinarians: A Persis-tent Problem, American Journal of Industrial Medicine, 46 (2004), 4, pp. 386-392
Davis, M. L., Cornwell, D. A., Introduction to Environmental Engineering; McGraw-Hill: New York, USA, 1991
Zavaleta, D., Wilson, W. O., Poultry House Dust, Odours and Feathers A Review, World’s Poultry Sci. J., 32 (1976), 4, pp. 333-338
Rosentrater, K. A. Performance of an Electrostatic Dust Collection System in Swine Facilities, Agric. Eng. Int.: CIGR J. Sci. Res. Dev. Manuscript BC 03 003, Vol. 5, 2003
Phillips, V. R., et al., The Development of Robust Methods for Measuring Concentrations and Emission Rates of Gaseous and Particulate Air Pollutants in Livestock Buildings, Journal of Agricultural Engi-neering Research 70 (1998), 1, pp. 11-24
Grantz, D. A., Ecological Effects of Particulate Matter, Environment International, 29 (2003), 2-3, pp. 213-239
Cambra-Lopez Maria., Control of Particulate Matter Emissions from Poultry and Pig Houses, Ph. D. thesis, University of Valencia, Valencia, Spain, 2010
Amuhanna, E., Dust Control in Livestock Buildings with Electrostatically Charged Water Spray, Ph. D. thesis, Kansas State University, ManhattaN, Kann., USA, 2007
Ogink, N. W. M., Aarnink, A. J. A., Removal of PM10 and PM2.5 by Combined Air Scrubbers in Live-stock Operations, Proceedings, How to Improve Air Quality. International Conference, Maastricht, The Netherlands, 2007
Ogink, N. W. M., et al., Multi-Pollutant and One-Stage Scrubbers for Removal of Ammonia, Odor and Particulate Matter from Animal House Exhaust Air, Proceedings, International Symposium Livestock and Environment, ILES VIII, Iguassu, Brazil, 2008
Zhao, Y., et al., Removal Efficiency of Dust and Bacteria by Multi-Stage Air Scrubbers in a Pig House, Proceedings, International Symposium Livestock and Environment, ILES VIII, Iguassu, Brazil, 2008
Cambra-Lopez, Maria., Airborne Particulate Matter from Livestock Production Systems: A Review of an Air Pollution Problem, Environmental Pollution, 158 (2010), 1, pp. 1-17
OECD, Environmental Performance of Agriculture in OECD Countries Since 1990, Paris, France, OECD, 2008
Costantino, A., et al., Energy Use for Climate Control of Animal Houses: The State of the Art in Europe. Energy Proc., 101 (2016), Nov., pp. 184-191
Jerez, S. B., et al., Quantification of Ventilation Effectiveness for Air Quality Control in Animal Build-ings, Proceedings, ASHRAE Transactions - ASHRAE Winter Conference (PART 1 ed., pp. 460-468). (ASHRAE Transactions; Vol. 120, No. PART 1). Amer. Soc. Heating, Ref. Air-Conditioning Eng. Inc, 2014
St-Pierre, N. R., et al., Economic Losses from Heat Stress by US Livestock Industries, J. Dairy Sci. 86 (2003), Suppl., pp. E52-E77
Zhao, Y., Effectiveness of Multi-Stage Scrubbers in Reducing Emission of Air Pollutants from Pig Houses, ASABE, 54 (2011), 1, pp. 285-293